Description
The Feuling Camplate PSI Relief Valve Tester Tool is a must-have for any Harley-Davidson Twin Cam engine builder. This tool allows you to accurately check the PSI at which the camplate relief valve opens, ensuring correct oil pressure and engine operation.
Features include an adjustable spring tension for setting the desired pop-off PSI, an air regulator, a 0-100 PSI pressure gauge, gasket, and all necessary mounting hardware. Fits all factory and aftermarket Twin Cam camplates. For 2007-2017 models, one bolt hole will be unused.
Feuling® recommends the camplate valve be seated at 0-30 PSI with a full pop-off at 55-60 PSI. Bench test your camplate before installation by cycling the pressure relief valve to ensure it moves freely, seats, and seals correctly every time. Any leakage at the relief valve will reduce oil pressure.
Made in the USA.